Rolling Mill




1- Application: Billet temperature measurement before entering the rolling


Process Temperature: 1000°C

Installation of the Pyrometer: Targeted on billet


추천 온도계 : A450


 
   A450 Pyrometers


2- Application: Before Quenching


Process Temperature: 900-950°C

Installation of the Pyrometer: Before quenching


추천 온도계 : A450


 

   A450 Pyrometers



3- Application: After Quenching at the cooling bed.


At the cooling bed, temperature equalizing takes place around 600ºC.This makes the surface of the re-bar a hardened structure.

The core remains soft. Monitoring and controlling temperature at each stage is important to maintain the quality of Re-Bars.

Cooling is important factor here. To ensure the retention of all the metallurgical properties of the steel the cooling should be fast as

well as controlled. Lack of control in the cooling will lead to the formation of scrape/wastage material. This will hamper the quality of the product.

Installation of the pyrometer at this level helps in Retention of the metallurgical properties of the steel, helps in monitoring a variety of rod/bars with

different diameters and in carrying out continuous temperature measurement.




Process Temperature: 450°C-500°C

Installation of the Pyrometer: At the cooling bed


추천 온도계 : A250


 

   A250 Pyrometers